Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 74
Filter
1.
Ultrasonography ; : 519-529, 2022.
Article in English | WPRIM | ID: wpr-939270

ABSTRACT

Purpose@#This study investigated the utility of second-line contrast-enhanced ultrasonography (CEUS) using Sonazoid in Liver Imaging Reporting and Data System category 3 (LR-3) and 4 (LR-4) observations on gadoxetate-enhanced magnetic resonance imaging (MRI). @*Methods@#This retrospective study included LR-3 or LR-4 observations on gadoxetate-enhanced MRI subsequently evaluated with CEUS from 2013 to 2017. The presence of MRI features, CEUSarterial phase hyperenhancement (CEUS-APHE), and Kupffer phase defect (KPD) was evaluated. Multivariable logistic regression analysis was performed to identify significant imaging features associated with the diagnosis of hepatocellular carcinoma (HCC). The optimal diagnostic criteria were investigated using the McNemar test. @*Results@#In total, 104 patients with 104 observations (63 HCCs) were included. The presence of both CEUS-APHE and KPD on CEUS enabled the additional detection of 42.3% (11/26) of LR-3 HCCs and 78.4% (29/37) of LR-4 HCCs. Transitional phase (TP) hypointensity (adjusted odds ratio [OR], 10.59; P<0.001), restricted diffusion (adjusted OR, 7.55; P=0.004), and KPD (adjusted OR, 7.16; P=0.003) were significant imaging features for HCC diagnosis. The presence of at least two significant imaging features was optimal for HCC diagnosis (sensitivity, specificity, and accuracy: 88.9%, 78.1%, and 84.6%, respectively), with significantly higher sensitivity than the presence of both CEUS-APHE and KPD (sensitivity, specificity, and accuracy: 63.5% [P=0.001], 92.7% [P=0.077], and 75.0% [P=0.089], respectively). @*Conclusion@#The combined interpretation of gadoxetate-enhanced MRI and second-line CEUS using Sonazoid, focusing on TP hypointensity, restricted diffusion, and KPD, may be optimal for further characterizing LR-3 and LR-4 observations.

2.
Korean Journal of Radiology ; : 615-624, 2022.
Article in English | WPRIM | ID: wpr-926759

ABSTRACT

Objective@#To compare the therapeutic outcomes of laparoscopic hepatic resection (LHR) and laparoscopic radiofrequency ablation (LRFA) for single subcapsular hepatocellular carcinoma (HCC). @*Materials and Methods@#We screened 244 consecutive patients who had received either LHR or LRFA between January 2014 and December 2016. The feasibility of LRFA in patients who underwent LHR was retrospectively assessed by two interventional radiologists. Finally, 60 LRFA-feasible patients who had received LHR and 29 patients who had received LRFA as the first treatment for a solitary subcapsular HCC between 1 cm and 3 cm were finally included. We compared the therapeutic outcomes, including local tumor progression (LTP), recurrence-free survival (RFS), and overall survival (OS) between the two groups before and after propensity score (PS) matching. Multivariable Cox proportional hazard regression was also used to evaluate the difference in OS and RFS between the two groups for all 89 patients. @*Results@#PS matching yielded 23 patients in each group. The cumulative LTP and OS rates were not significantly different between the LHR and LRFA groups after PS matching (p = 0.900 and 0.003, respectively). The 5-year LTP rates were 4.6% and 4.4%, respectively, and OS rates were 100% and 90.7%, respectively. The RFS rate was higher in LHR group without statistical significance (p = 0.070), with 5-year rates of 78.3% and 45.3%, respectively. OS was not significantly different between the LHR (reference) and LRFA groups in multivariable analyses, with a hazard ratio (HR) of 1.33 (95% confidence interval, 0.12–1.54) (p = 0.818). RFS was higher in LHR (reference) than in LRFA without statistical significance in multivariable analysis, with an HR of 2.01 (0.87–4.66) (p = 0.102). @*Conclusion@#There was no significant difference in therapeutic outcomes between LHR and LRFA for single subcapsular HCCs measuring 1–3 cm. The difference in RFS should be further evaluated in a larger study.

3.
Ultrasonography ; : 486-498, 2021.
Article in English | WPRIM | ID: wpr-919548

ABSTRACT

Purpose@#The aim of this study was to evaluate the association of contrast-enhanced ultrasound (CEUS) features using Sonazoid for liver nodules with Liver Imaging Reporting and Data System (LI-RADS) categories and to identify the usefulness of Kupffer-phase images. @*Methods@#This retrospective study was conducted in 203 patients at high risk of hepatocellular carcinoma (HCC) who underwent CEUS with Sonazoid from 2013 to 2016. Nodule enhancement in the arterial, portal venous, late, and Kupffer phases; CEUS LI-RADS major features; and Kupffer-phase defects were evaluated. According to the computed tomography/magnetic resonance imaging (CT/MRI) LI-RADS v2018, all nodules were assigned an LR category (n=4/33/99/67 for LR-M/3/4/5) and comparisons across LR categories were made. We defined modified CEUS LI-RADS as using Kupffer-phase defects as an alternative to late and mild washout in CEUS LI-RADS and compared the diagnostic performance for HCC. @*Results@#On CEUS of 203 nodules, 89.6% of CT/MRI LR-5 and 85.9% of LR-4 nodules showed hyperenhancement in the arterial phase, while 57.6% of LR-3 nodules showed hyperenhancement. Among the CT/MRI LR-5 nodules that showed arterial phase hyperenhancement or isoenhancement, 59.7% showed hypoenhancing changes from the portal venous phase, 23.9% from the late phase, and 13.4% additionally in the Kupffer phase. The modified CEUS LI-RADS showed higher sensitivity than CEUS LI-RADS (83.2% vs. 74.2%, P=0.008) without compromising specificity (63.6% vs. 69.7%, P=0.500). @*Conclusion@#The Kupffer phase best shows hypoenhancing changes in LR-5 lesions and is expected to improve the sensitivity for HCC in high-risk patients.

4.
Ultrasonography ; : 274-280, 2021.
Article in English | WPRIM | ID: wpr-919491

ABSTRACT

Purpose@#This study investigated which body position is more useful for visualizing subphrenic hepatocellular carcinomas (HCCs) during ultrasonography (US) examinations. @*Methods@#This prospective study was approved by the institutional review board and written informed consent was obtained from all patients. Twenty consecutive patients with a single subphrenic HCC (treatment-naïve, 1 to 3 cm) underwent a US examination for planning radiofrequency ablation. The examinations were done by one of three radiologists and the patients were examined in four different body positions-supine, right posterior oblique (RPO), left lateral decubitus (LLD), and semi-erect-by being positioned on a tilted table. The visibility of the index tumor was prospectively assessed using a 4-point scale. Needle insertion was considered to be technically feasible if the visibility score was lower than 2. The visibility score and technical feasibility were compared using the Wilcoxon signed rank test and the McNemar test, respectively, for pairwise comparisons between different body positions. @*Results@#The visibility score was significantly lower in the semi-erect position (median, 2; interquartile range, 1 to 2.75) than in the supine (3, 2 to 4), RPO (3, 2 to 4), and LLD (4, 3.25 to 4) positions (P=0.007, P=0.005, and P=0.001, respectively). The technical feasibility of needle insertion was also significantly higher in the semi-erect position (75%, 15/20) than in the supine (45%, 9/45), RPO (35%, 7/20), and LLD (20%, 4/20) positions (P=0.031, P=0.021, and P=0.001, respectively). @*Conclusion@#The semi-erect position is more useful for the visualization of subphrenic HCCs than the supine, RPO, or LLD positions.

5.
Korean Journal of Radiology ; : 1077-1086, 2020.
Article | WPRIM | ID: wpr-833586

ABSTRACT

Objective@#To evaluate the effect of perfluorobutane microbubbles (Sonazoid®, GE Healthcare) on steam popping duringradiofrequency (RF) ablation for treating hepatocellular carcinoma (HCC), and to assess whether popping affects treatmentoutcomes. @*Materials and Methods@#The institutional review board approved this retrospective study, which included 90 consecutivepatients with single HCC, who received percutaneous RF ablation as the first-line treatment. The patients were divided intotwo groups, based on the presence or absence of the popping phenomenon, which was defined as an audible sound with asimultaneous sudden explosion within the ablation zone as detected via ultrasonography during the procedure. The factorscontributing to the popping phenomenon were identified using multivariable logistic regression analysis. Local tumor progression(LTP) and disease-free survival (DFS) were assessed using the Kaplan-Meier method with the log-rank test for performingcomparisons between the two groups. @*Results@#The overall incidence of the popping phenomenon was 25.8% (24/93). Sonazoid® was used in 1 patient (4.2%) inthe popping group (n = 24), while it was used in 15 patients (21.7%) in the non-popping group (n = 69). Multivariableanalysis revealed that the use of Sonazoid® was the only significant factor for absence of the popping phenomenon (oddsratio = 0.10, p= 0.048). There were no significant differences in cumulative LTP and DFS between the two groups (p= 0.479and p= 0.424, respectively). @*Conclusion@#The use of Sonazoid® has a suppressive effect on the popping phenomenon during RF ablation in patients withHCC. However, the presence of the popping phenomenon may not affect clinical outcomes.

6.
Korean Journal of Radiology ; : 633-646, 2020.
Article | WPRIM | ID: wpr-833563

ABSTRACT

We reviewed all studies assessing the health-related quality of life (HRQoL) in patients with hepatocellular carcinoma (HCC) between 2009 and 2018 (n = 45). Most studies assessed HRQoL as an outcome, and evaluated or compared the HRQoL of HCC patients depending on the type of treatment or stage of disease. HCC patients had a worse HRQoL than the general population, including in those with early-stage HCC. Patients commonly experienced pain, fatigue, sleep disturbance, distress, and lack of appetite, and these symptoms remained problematic even a few years after treatment. TNM classification of malignant tumors stage, tumor stage, presence of cirrhosis, being Asian, being female, living alone, or being unemployed were associated with a poor HRQoL. While recent studies have included a more diverse patient population, various topics, and different study designs, there were limited studies on supportive interventions. Given the increase in HCC cases and HCC survivors, addressing the HRQoL of HCC patients requires more attention.

7.
Korean Journal of Radiology ; : 173-179, 2017.
Article in English | WPRIM | ID: wpr-208827

ABSTRACT

OBJECTIVE: To evaluate the in vivo efficiency of the biopsy tract radiofrequency ablation for hemostasis after core biopsy of the liver in a porcine liver model, including situations with bleeding tendency and a larger (16-gauge) core needle. MATERIALS AND METHODS: A preliminary study was performed using one pig to determine optimal ablation parameters. For the main experiment, four pigs were assigned to different groups according to heparinization use and biopsy needle caliber. In each pig, 14 control (without tract ablation) and 14 experimental (tract ablation) ultrasound-guided core biopsies were performed using either an 18- or 16-gauge needle. Post-biopsy bleeding amounts were measured by soaking up the blood for five minutes. The results were compared using the Mann-Whitney U test. RESULTS: The optimal parameters for biopsy tract ablation were determined as a 2-cm active tip electrode set at 40-watt with a tip temperature of 70–80℃. The bleeding amounts in all experimental groups were smaller than those in the controls; however they were significant in the non-heparinized pig biopsied with an 18-gauge needle and in two heparinized pigs (p < 0.001). In the heparinized pigs, the mean blood loss in the experimental group was 3.5% and 13.5% of the controls biopsied with an 18- and 16-gauge needle, respectively. CONCLUSION: Radiofrequency ablation of hepatic core biopsy tract ablation may reduce post-biopsy bleeding even under bleeding tendency and using a larger core needle, according to the result from in vivo porcine model experiments.


Subject(s)
Biopsy , Biopsy, Large-Core Needle , Catheter Ablation , Electrodes , Hemorrhage , Hemostasis , Heparin , Liver , Needles , Pulsed Radiofrequency Treatment , Swine
8.
Clinical and Molecular Hepatology ; : 95-101, 2017.
Article in English | WPRIM | ID: wpr-165802

ABSTRACT

Image-guided radiofrequency ablation (RFA) is an evolving and growing treatment option for patients with hepatocellular carcinoma (HCC) and hepatic metastasis. RFA offers significant advantages as it is less invasive than surgery and carries a low risk of major complications. However, serious complications, including aggressive tumor recurrence, may be observed during follow-up, and recently, mechanical or thermal damage during RFA has been proposed to be one of the causes of this kind of recurrence. Although the exact mechanism of this still remains unclear, physicians should be familiar with the imaging features of aggressive tumor recurrence after RFA for HCC and its risk factors. In addition, in order to prevent or minimize this newly recognized tumor recurrence, a modified RFA technique, combined RFA treatments with transarterial chemoembolization, and cryoablation can be used as alternative treatments. Ultimately, combining an understanding of this potential complication of RFA with an understanding of the possible risk factors for aggressive tumor recurrence and choosing alternative treatments are crucial to optimize clinical outcomes in each patient with HCC.


Subject(s)
Humans , Carcinoma, Hepatocellular , Catheter Ablation , Cryosurgery , Follow-Up Studies , Liver , Neoplasm Metastasis , Recurrence , Risk Factors
9.
Clinical and Molecular Hepatology ; : 295-299, 2015.
Article in English | WPRIM | ID: wpr-157198

ABSTRACT

Intravascular large B-cell lymphoma (IVLBCL) is a rare subtype of extranodal diffuse large B-cell lymphoma that most commonly involves the central nervous system and skin. To our knowledge, no state-of-the art imaging findings have been reported for hepatic IVLBCL in the English literature. We report the first case of hepatic involvement of IVLBCL along with a literature review.


Subject(s)
Humans , Male , Middle Aged , Antigens, CD20/metabolism , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Liver Neoplasms/drug therapy , Lymphoma, Large B-Cell, Diffuse/drug therapy , Magnetic Resonance Imaging , Remission Induction , Rituximab/administration & dosage , Tomography, X-Ray Computed
10.
Korean Journal of Radiology ; : 95-107, 2014.
Article in English | WPRIM | ID: wpr-114851

ABSTRACT

OBJECTIVE: To perform a systematic review of compliance with standardized terminology and reporting criteria for radiofrequency (RF) tumor ablation, proposed by the International Working Group on Image-Guided Tumor Ablation in 2003, in the published reports. MATERIALS AND METHODS: Literature search in the PubMed database was performed using index keywords, PubMed limit system, and eligibility criteria. The entire content of each article was reviewed to assess the terminology used for procedure terms, imaging findings, therapeutic efficacy, follow-up, and complications. Accuracy of the terminology and the use of alternative terms instead of standard terminology were analyzed. In addition, disparities in accuracy of terminology in articles according to the medical specialty and the type of radiology journal were evaluated. RESULTS: Among the articles (n = 308) included in this study, the accuracy of the terms 'procedure or session', 'treatment', 'index tumor', 'ablation zone', 'technical success', 'primary technique effectiveness rate', 'secondary technique effectiveness rate', 'local tumor progression', 'major complication', and 'minor complication' was 97% (298/307), 97% (291/300), 8% (25/307), 65% (103/159), 55% (52/94), 33% (42/129), 94% (17/18), 45% (88/195), 99% (79/80), and 100% (77/77), respectively. The overall accuracy of each term showed a tendency to improve over the years. The most commonly used alternative terms for 'technical success' and 'local tumor progression' were 'complete ablation' and 'local (tumor) recurrence', respectively. The accuracy of terminology in articles published in radiology journals was significantly greater than that of terminology in articles published in non-radiology journals, especially in Radiology and The Journal of Vascular and Interventional Radiology. CONCLUSION: The proposal for standardization of terminology and reporting criteria for RF tumor ablation has been gaining support according to the recently published scientific reports, especially in the field of radiology. However, more work is still needed for the complete standardization of terminology.


Subject(s)
Female , Humans , Catheter Ablation , Guideline Adherence , Neoplasms/surgery , Terminology as Topic , Writing/standards
11.
Clinical and Molecular Hepatology ; : 61-70, 2014.
Article in English | WPRIM | ID: wpr-18374

ABSTRACT

BACKGROUND/AIMS: To determine the value of fusion imaging with contrast-enhanced ultrasonography (CEUS) and computed tomography (CT)/magnetic resonance (MR) images for percutaneous radiofrequency ablation (RFA) of very-early-stage hepatocellular carcinomas (HCCs) that are inconspicuous on fusion imaging with B-mode ultrasound (US) and CT/MR images. METHODS: This retrospective study was approved by our institutional review board and the requirement for informed consent was waived. Fusion imaging with CEUS using Sonazoid contrast agent and CT/MR imaging was performed on HCCs (<2 cm) that were inconspicuous on fusion imaging with B-mode US. We evaluated the number of cases that became conspicuous on fusion imaging with CEUS. Percutaneous RFA was performed under the guidance of fusion imaging with CEUS. Technical success and major complication rates were assessed. RESULTS: In total, 30 patients with 30 HCCs (mean, 1.2 cm; range, 0.6-1.7 cm) were included, among which 25 (83.3%) became conspicuous on fusion imaging with CEUS at the time of the planning US and/or RFA procedure. Of those 25 HCCs, RFA was considered feasible for 23 (92.0%), which were thus treated. The technical success and major complication rates were 91.3% (21/23) and 4.3% (1/23), respectively. CONCLUSIONS: Fusion imaging with CEUS and CT/MR imaging is highly effective for percutaneous RFA of very-early-stage HCCs inconspicuous on fusion imaging with B-mode US and CT/MR imaging.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Carcinoma, Hepatocellular/diagnosis , Catheter Ablation , Contrast Media , Ferric Compounds , Iron , Liver Neoplasms/diagnosis , Magnetic Resonance Imaging , Neoplasm Staging , Oxides , Retrospective Studies , Tomography, X-Ray Computed
12.
Korean Journal of Radiology ; : 754-763, 2013.
Article in English | WPRIM | ID: wpr-209700

ABSTRACT

OBJECTIVE: To determine whether pretreatment evaluation with contrast-enhanced ultrasonography (CEUS) is effective for percutaneous radiofrequency ablation (RFA) of hepatocellular carcinoma (HCC) with poor conspicuity on conventional ultrasonography (US). MATERIALS AND METHODS: This retrospective study was approved by the institutional review board and informed consent was waived. From June 2008 to July 2011, 82 patients having HCCs (1.2 +/- 0.4 cm) with poor conspicuity on planning US for RFA were evaluated with CEUS prior to percutaneous RFA. We analyzed our database, radiologic reports, and US images in order to determine whether the location of HCC candidates on planning US coincide with that on CEUS. To avoid incomplete ablation, percutaneous RFA was performed only when HCC nodules were identified on CEUS. The rate of technical success was assessed. The cumulative rate of local tumor progression was estimated with the use of the Kaplan-Meier method (mean follow-up: 24.0 +/- 13.0 months). RESULTS: Among 82 patients, 73 (89%) HCCs were identified on CEUS, whereas 9 (11%) were not. Of 73 identifiable HCCs on CEUS, the location of HCC on planning US corresponded with that on CEUS in 64 (87.7%), whereas the location did not correspond in 9 (12.3%) HCCs. Technical success was achieved for all 73 identifiable HCCs on CEUS in a single (n = 72) or two (n = 1) RFA sessions. Cumulative rates of local tumor progression were estimated as 1.9% and 15.4% at 1 and 3 years, respectively. CONCLUSION: Pretreatment evaluation with CEUS is effective for percutaneous RFA of HCCs with poor conspicuity on conventional US.


Subject(s)
Female , Humans , Male , Middle Aged , Carcinoma, Hepatocellular/surgery , Catheter Ablation/methods , Contrast Media , Follow-Up Studies , Liver Neoplasms/surgery , Neoplasm Staging , Preoperative Period , Retrospective Studies
13.
Clinical and Molecular Hepatology ; : 360-366, 2013.
Article in English | WPRIM | ID: wpr-34831

ABSTRACT

Hepatocyte specific contrast agents including gadoxetic acid and gadobenate dimeglumine are very useful to diagnose various benign and malignant focal hepatic lesions and even helpful to estimate hepatic functional reservoir. The far delayed phase image referred to as the hepatobiliary phase makes the sensitivity of detection for malignant focal hepatic lesions increased, but specificity of malignant diseases, including hepatocellular carcinoma, metastasis and cholangiocarcinoma, characterization remained to be undetermined.


Subject(s)
Humans , Carcinoma, Hepatocellular/diagnostic imaging , Cholangiocarcinoma/diagnostic imaging , Contrast Media/chemistry , Hemangioma/diagnostic imaging , Liver Diseases/diagnostic imaging , Liver Neoplasms/diagnostic imaging , Magnetic Resonance Imaging , Meglumine/analogs & derivatives , Organometallic Compounds/chemistry
14.
Korean Journal of Radiology ; : 433-440, 2010.
Article in English | WPRIM | ID: wpr-65185

ABSTRACT

OBJECTIVE: This study was designed to compare the diagnostic performance of gadoxetic acid-enhanced magnetic resonance imaging (MRI) with gadobenate dimeglumine-enhanced MRI for preoperatively detecting hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Eighteen consecutive patients (17 men and one woman, age range: 31-73 years) with 22 HCCs underwent examinations with gadoxetic acid enhanced MRI and gadobenate dimeglumine-enhanced MRI on a 3.0-Tesla unit. The diagnosis of HCC was established after surgical resection and pathological conformation. Three observers independently reviewed each MR image in a random order on a tumor-by-tumor basis. The diagnostic accuracy of these techniques for the detection of HCC was assessed by performing an alternative free-response receiver operating characteristic (ROC) analysis. The sensitivity and positive predictive values were evaluated. RESULTS: The average value of the area under the ROC curve (Az) for gadoxetic acid enhanced MRI (0.887) was not significantly different from the Az (0.899) for gadobenate dimeglumine-enhanced MRI (p > 0.05). The overall sensitivities of gadoxetic acid enhanced MRI and gadobenate dimeglumine-enhanced MRI were 80% and 83%, respectively, with no significant difference (p > 0.05). The differences of the positive predictive values for the two contrast agents for each observer were not statistically significant (p > 0.05). CONCLUSION: The diagnostic performance of gadoxetic acid-enhanced MRI and gadobenate dimeglumine-enhanced MRI for preoperatively detecting HCC is quite similar.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Carcinoma, Hepatocellular/diagnosis , Gadolinium DTPA , Image Interpretation, Computer-Assisted , Liver Neoplasms/diagnosis , Magnetic Resonance Imaging/methods , Meglumine/analogs & derivatives , Organometallic Compounds , Predictive Value of Tests , ROC Curve , Sensitivity and Specificity , Statistics, Nonparametric
15.
Korean Journal of Radiology ; : 291-302, 2008.
Article in English | WPRIM | ID: wpr-173070

ABSTRACT

High-intensity focused ultrasound therapy is a novel, emerging, therapeutic modality that uses ultrasound waves, propagated through tissue media, as carriers of energy. This completely non-invasive technology has great potential for tumor ablation as well as hemostasis, thrombolysis and targeted drug/gene delivery. However, the application of this technology still has many drawbacks. It is expected that current obstacles to implementation will be resolved in the near future. In this review, we provide an overview of high-intensity focused ultrasound therapy from the basic physics to recent clinical studies with an interventional radiologist's perspective for the purpose of improving the general understanding of this cutting-edge technology as well as speculating on future developments.


Subject(s)
Humans , Drug Delivery Systems , Gene Targeting , Hemostatic Techniques , Thrombolytic Therapy/methods , Ultrasonic Therapy/methods
16.
Korean Journal of Radiology ; : 325-332, 2008.
Article in English | WPRIM | ID: wpr-173066

ABSTRACT

OBJECTIVE: To evaluate the three-phase helical CT features of early hepatocellular carcinomas, based on the new Japanese classification. MATERIALS AND METHODS: Over the course of an eight-year period, we collected 16 pathologically proven early hepatocellular carcinomas from 16 patients having undergone a three-phase helical CT prior to surgery. The three-phase CT images were acquired at 20-35 sec (arterial phase), 70 sec (portal phase), and 180 sec (equilibrium phase) from the begining of intravenous injection of contrast material. All the CT images were retrospectively analyzed by two radiologists in consensus, based on their description of morphologic (size, margin, fibrous capsule and mosaic pattern) and enhancement patterns of tumors. RESULTS: Only seven (44%) of the 16 early hepatocellular carcinomas having undergone a CT were described (mean diameter, 1.2 cm; range, 0.4-2.5 cm). All the tumors had an ill-defined margin with no fibrous capsule. The mosaic pattern was found in only one tumor. Only three (43%) of the seven tumors detected on CT were hyperattenuating during the arterial phase. The four remaining tumors (25%) were hypoattenuating throughout the three phases. CONCLUSION: Despite the higher resolution provided by the three phase scans, the contrast-enhanced CT provides only limited detection of the variable morphologic and enhancement features of early hepatocellular carcinomas.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Carcinoma, Hepatocellular/pathology , Liver Neoplasms/pathology , Retrospective Studies , Tomography, Spiral Computed
17.
The Korean Journal of Hepatology ; : 439-443, 2006.
Article in English | WPRIM | ID: wpr-96789

ABSTRACT

Needle tract implantation of hepatocellular carcinoma (HCC) is a rare complication of percutaneous biopsy, and it is largely associated with end-cutting needles or aspiration biopsy. The CT findings that have been reported include oval or round soft tissue nodules with persistent contrast enhancement along the needle tract, mostly in the subcutaneous tissue or the intercostal muscle layers. In this report, we describe a case of needle tract implantation of HCC after US-guided percutaneous biopsy with an 18G tru-cut needle.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Biopsy, Needle/adverse effects , Carcinoma, Hepatocellular/diagnostic imaging , Liver Neoplasms/pathology , Neoplasm Seeding , Radiography, Abdominal , Retrospective Studies , Tomography, Spiral Computed
18.
Journal of the Korean Radiological Society ; : 117-127, 2005.
Article in Korean | WPRIM | ID: wpr-42579

ABSTRACT

PURPOSE: The purpose of this study was to establish a quality standard for mammographic equipment in Korea and to eventually improve mammographic quality in clinics and hospitals throughout Korea by educating technicians and clinic personnel. MATERIALS AND METHODS: For the phantom test and on site assessment, we visited 37 sites and examined 43 sets of mammographic equipment. Items that were examined include phantom test, radiation dose measurement, developer assessment, etc. The phantom images were assessed visually and by optical density measurements. For the clinical image assessment, clinical images from 371 sites were examined following the new Korean standard for clinical image evaluation. The items examined include labeling, positioning, contrast, exposure, artifacts, collimation among others. RESULTS: Quality standard of mammographic equipment was satisfied in all equipment during on site visits. Average mean glandular dose was 114.9 mRad. All phantom image test scores were over 10 points (average, 10.8 points). However, optical density measurements were below 1.2 in 9 sets of equipment (20.9%). Clinical image evaluation revealed appropriate image quality in 83.5%, while images from non-radiologist clinics were adequate in 74.6% (91/122), which was the lowest score of any group. Images were satisfactory in 59.0% (219/371) based on evaluation by specialists following the new Korean standard for clinical image evaluation. Satisfactory images had a mean score of 81.7 (1 S.D.=8.9) and unsatisfactory images had a mean score of 61.9 (1 S.D=11). The correlation coefficient between the two observers was 0.93 (p<0.01) in 49 consecutive cases. CONCLUSION: The results of the phantom tests suggest that optical density measurements should be performed as part of a new quality standard for mammographic equipment. The new clinical evaluation criteria that was used in this study can be implemented with some modifications for future mammography quality control by the Korean government.


Subject(s)
Artifacts , Korea , Mammography , Quality Control , Specialization
19.
Journal of the Korean Radiological Society ; : 353-362, 2005.
Article in English | WPRIM | ID: wpr-56284

ABSTRACT

PURPOSE: We wanted to evaluate the diverse distribution and relation of the hepatic segments, as divided by the portal venous territories, on the isotropic multi-planar reformatted (MPR) CT images and we wanted to find their correlation to the intrahepatic venous structures. MATERIALS AND METHODS: Fifty adult patients who underwent portal phase CT images and who had the normal liver contours at CT were included in our study. The portal phase images were obtained with a slice collimation and reconstruction interval of 1.25 mm, and they were reformatted in the coronal and sagittal planes with a slab thickness of 3 mm. For analysis of these MPR images, various terms were newly defined according to the portal venous territories (e.g., three vertical planes [right, middle and left] and one transverse plane and their plane angles, the transverse and longitudinal angles). Also, the dominant segments of the right lobe were newly divided into the S7- and S8-dominant types by comparing the transverse angles. The imaging analysis was then conducted for the following: (1) the diversity of the three vertical planes and the one transverse plane and their plane angles, (2) the proportion of the dominant segments of the right lobe and their relation with the plane angles, and (3) the correlation between the dominant segments and the intrahepatic venous structures. RESULTS: The number of the S7- and the S8-dominant types was 21 and 29, respectively. The vertical and transverse planes were undulating and diverse according to the dominant segments as follows: the plane angles of the right vertical and middle vertical planes were more vertical in the S7-dominant type than in the S8-dominant type (p < 0.001). The right transverse plane angle was more horizontal in the S8-dominant type (p < 0.05). The left transverse plane angle seemed to be rather vertical than horizontal. For the intrahepatic venous structures, despite of our limited data, the anomalous intrahepatic venous structures might have some correlation with the dominant segments. CONCLUSION: According to our results, we suggest that the isotropic MPR images could successfully depict the vertical and transverse planes of the real hepatic segments, as divided by the portal venous territories, which were diverse according to their dominant types.


Subject(s)
Adult , Humans , Liver
20.
Journal of the Korean Radiological Society ; : 307-312, 2004.
Article in Korean | WPRIM | ID: wpr-49109

ABSTRACT

PURPOSE: To evaluate the usefulness of screening liver ultrasonography (US) for hepatocellular carcinoma (HCC) detection in patients with chronic hepatitis or hepatic cirrhosis caused by hepatitis B virus (HBV). MATERIALS AND METHODS: A retrospective study was performed with 1,189 patients with clinical hepatopathy caused by HBV who underwent screening liver US for HCC detection at least twice. All patients were followed up with liver US examinations (mean, 8.3 times), CT, or MR for at least 3 months (range, 3-102 months; mean, 47 months) for the detection of HCC. The study population was divided into two groups: chronic hepatitis (n=492) and hepatic cirrhosis (n=697), which was further divided into two groups with (n=156) or without (n=541) evident shrinkage. The radiologic examinations that had detected HCC for the first time were analyzed and compared between the groups. RESULTS: Among 20 (4.1%) patients with chronic hepatitis and 132 (18.9%) patients with hepatic cirrhosis diagnosed as HCC, screening US was the modality of detection in 17 (85.0%) of 20 patients with chronic hepatitis and 76 (57.6%) of 132 patients with hepatic cirrhosis (p=0.038, Chi-square test). The detection rate of HCC on screening US between the chronic hepatitis and hepatic cirrhosis with evident shrinkage (51.4%, 19/37) showed a significant difference (p=0.027, Chi-square test). CONCLUSION: For chronic liver disease caused by HBV, screening US for HCC detection is more useful in patients with chronic hepatitis than with hepatic cirrhosis with evident shrinkage.


Subject(s)
Humans , Carcinoma, Hepatocellular , Early Detection of Cancer , Hepatitis B virus , Hepatitis B , Hepatitis , Hepatitis, Chronic , Liver , Liver Cirrhosis , Liver Diseases , Mass Screening , Retrospective Studies , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL